TP67 : OnkoRisk Women's Hereditary Cancer Panel (Non-NYS)
INFORMATION:
Alternate Name:
OnkoRisk WH (Non-NYS)
Methodology:
Genotyping by Next Generation Sequencing
Clinical Utility:
19 gene panel content focused on hereditary breast and ovarian cancer syndromes. This includes sequencing and deletion/duplication analysis. Non-NY only.
Genes:
ATM
BARD1
BRCA1
BRCA2
BRIP1
CDH1
CHEK2
EPCAM
MLH1
MSH2
MSH6
NF1
PALB2
PMS2
PTEN
RAD51C
RAD51D
STK11
TP53
ORDERING:
Test Code:
TP67-5
Turnaround Time:
14 DAYS
Preferred Specimen:
5-6 mL Peripheral Blood - Lavender Top
Collection:
Container | Qty | Temp | Stability |
---|---|---|---|
Peripheral Blood - Lavender Top | 2 | Room Temp |
Collection Instructions:
LPB: Fill tube, invert gently 5-6 times, label with patient's name
Storage Transport Instructions:
Custom Instruction: Lavender: 2 tubes (5-6ml each) Label with the patient name, date of birth and/or ID. Ideal handling is to ship immediately at ambient temperature for overnight delivery.
Alternate sample type: DNA: Extract and submit DNA =50 ng/µL AND a volume of =100 µL in sterile container. 1.7 mL flip-cap microtube, 1.5 mL v-bottom screw cap tube, 0.5 mL v-bottom skirted tube or 2.0 mL v-bottom skirted tube is preferred. Ship DNA in sealed and protective packaging at ambient temperature, using a cool pack in hot weather. Labeling: Name of person or identifier, DNA concentration and volume MUST be provided on the specimen tube. Extracted DNA is acceptable, providing that the isolation of nucleic acid occurs in a CLIA-certified laboratory or a laboratory meeting equivalent requirements as determined by CMS and/or the CAP.
ORAcollect®•Dx device (catalog number OCD-100): Carefully read all instructions provided in the kit for the saliva sample collection instructions. Label with patient’s name, date of birth and/or ID.
Alternate sample type: DNA: Extract and submit DNA =50 ng/µL AND a volume of =100 µL in sterile container. 1.7 mL flip-cap microtube, 1.5 mL v-bottom screw cap tube, 0.5 mL v-bottom skirted tube or 2.0 mL v-bottom skirted tube is preferred. Ship DNA in sealed and protective packaging at ambient temperature, using a cool pack in hot weather. Labeling: Name of person or identifier, DNA concentration and volume MUST be provided on the specimen tube. Extracted DNA is acceptable, providing that the isolation of nucleic acid occurs in a CLIA-certified laboratory or a laboratory meeting equivalent requirements as determined by CMS and/or the CAP.
ORAcollect®•Dx device (catalog number OCD-100): Carefully read all instructions provided in the kit for the saliva sample collection instructions. Label with patient’s name, date of birth and/or ID.
Alternative Specimen:
Eppendorf tube, OraCollect Dx Swab
Billing:
CPT Codes:
81432 x 1
CPT Code Disclaimer
CPT codes provided are for informational purposes only. Accuracy of CPT presented should be validated prior to consideration for billing.
CPT coding is the sole responsibility of the billing party. Please direct any questions regarding CPT coding to the payer being billed.